Jump to: navigation, search

log-extended



     


logger-instr-id

Default Value: com.genesyslab.platform:level=fatal
Valid Values: io.netty.channel.nio.NioEventLoop:level=[trace, debug, info, warn, error, fatal]
Changes Take Effect: After restart
Introduced: 9.0.000.07 in Classification Server, 9.0.000.07 in Training Server

Specifies an appropriate level of logging for the underlying Netty library. The normal setting for the level of info is fatal. This level is chosen to avoid the excessive logging info.

logger-psdk

Default Value: com.genesyslab.platform:level=fatal
Valid Values: com.genesyslab.platform:level=[trace, debug, info, warn, error, fatal]
Changes Take Effect: After restart
Introduced: 9.0.000.02 in Classification Server, 9.0.000.07 in Training Server

Specifies a level of logging for the PSDK library. The normal setting for the level of info is “fatal”. This level is chosen to avoid the excessive logging info. For more information on the options in the '“log-extended'” section refer to the Genesys documentation. See also: logger-<id>.