Jump to: navigation, search

cpd Service Parameters for IVR Profile Provisioning

Use these parameters to configure Call Progress Detection (cpd):

Description Valid values Default value Takes effect
cpd-allowed (CPD Allowed)
Controls whether CPD service is allowed true: CPD service is allowed

false: CPD service is not allowed

true immediately
cpd-capability-requirement (CPD Capability Requirement)
This parameter specifies the required capability for when the cpd service is invoked in the context of an application. Use this format:

[cap_NameA]=[cap_ValueA1],...,[cap_ValueAm]; [cap_NameB]=[cap_ValueB1],...,[cap_ValueBn]; ; [cap_NameM]=[cap_ValueM1],...,[cap_ValueMi]
The set of [cap_NameX] must be unique.

(blank) immediately
cpd-forbidden-respcode (CPD Forbidden Response Code)
Expects parameter value of the form sipcode;description or just sipcode. 403 immediately
cpd-forbidden-set-alarm (Raise Alarm when CPD is Not Allowed)
If set to true, an alarm will be raised for the corresponding policy violation true

false

false immediately
cpd-level2-burst-limit (CPD level2 Usage Limit)
CPD application level2 usage limit The value must be an integer (blank) immediately
cpd-level3-burst-limit (CPD level3 Usage Limit)
CPD application level3 usage limit The value must be an integer (blank) immediately
cpd-usage-limit (CPD Usage Limit)
CPD application usage limit The value must be an integer (blank) immediately
cpd-usage-limit-exceeded-respcode (CPD Usage Limit Exceeded Response Code)
Expects parameter value of the form sipcode;desc or just sipcode. 480 immediately
cpd-usage-limit-exceeded-set-alarm (Raise Alarm for CPD Usage Limit Exceeded)
If set to true, an alarm will be raised for the corresponding policy violation true

false

false immediately
cpd-usage-limit-per-session (CPD Usage Limit per Session)
CPD application usage limit per call The value must be an integer (blank) immediately
This page was last edited on July 1, 2016, at 18:32.