Jump to: navigation, search

snmp Section



  


bulk.size

Default Value: 50
Valid Values: An integer greater than 0
Changes Take Effect:


The maximum number of entries that will be retrieved by a single SNMP GetBulk request. Note that this setting maybe be overriden by client configuration and packet size limit.

polling.interval

Default Value: 60
Valid Values: An integer greater than 0
Changes Take Effect:


The interval between each SNMP request to a specific component.

timeout

Default Value: 30000
Valid Values: An integer greater or equal to 1000
Changes Take Effect: immediately


The maximum amount of time the SNMP query will wait to receive the response from the SNMP Agent.