As of Friday October 16th, access to restricted content on this site now requires you to log in with your Genesys account. If you don't have an account, you can request one at these locations: Request MyPartner Portal Account or Request My Support Account.
Jump to: navigation, search

Section: queue-presence

error-level

  • Default Value: 10
  • Valid Values: A positive integer or a double value.
  • Changes take effect: When the application is started or restarted.
  • Description: The queuePresenceErrorLevel value. The value at which a statistic is considered to be at the upper threshold level.

statistic-name

  • Default Value: CurrNumberWaitingCalls
  • Valid Values: The name of a statistic server statistic queue.
  • Changes take effect: When the application is started or restarted.
  • Description: The queuePresenceStatisticName value. The name of the statistic that is used to evaluate presence for queues.

statistic-text

  • Default Values: interaction(s) waiting
  • Valid Value: Letters A to Z and a to z. Numbers 0 through 9. The underscore and space characters.
  • Changes take effect: When the application is started or restarted.
  • Description: The queuePresenceStatisticText value. The text that is displayed next to the statistic value.

warning-level

  • Default Value: 5
  • Valid Values: A positive integer or a double value.
  • Changes take effect: When the application is started or restarted.
  • Description: The queuePresenceWarningLevel value. The value at which a statistic is considered to be at the warning level.