Options Section



     


CharSet

Default Value: No default value
Valid Values: Any standard character set value
Changes Take Effect: Immediately
Dependencies: None

Specifies the character set for Notifications. Set this option value if Notifications contain specific locale characters that are not presented correctly in the message when received. For example, enter x-sjis for the Japanese character set.

NameOrder

Default Value: 1
Valid Values: 1, 2, 3
Changes Take Effect: Immediately
Dependencies: None

This option is mandatory.

Specifies the order of first and last names when sending e-mail notifications.

  • 1—First name is presented first.
  • 2—Last name is presented first.
  • 3—Last name is presented first and is separated from first name with a comma.

pollTimer

Default Value: 1
Valid Values: Any positive integer
Changes Take Effect: After restart
Dependencies: None

This option is mandatory.

Specifies how often (in minutes) WFM Daemon performs verification of data updates.

ReportGenerationTimeout

Default Value: 120
Valid Values: 1-1440
Changes Take Effect: After restart
Dependencies: None

Specifies the time (in minutes) after which a scheduled report task will be terminated, whether or not report is finished. Use this option to control how long scheduled report tasks can run.

TrackAhead

Default Value: 0
Valid Values: Any integer, positive or negative
Changes Take Effect: After restart
Dependencies: TrackBack

This option is mandatory.

Specifies the number of days in advance of the current date that WFM Daemon requests data from WFM Server. Relevant for any type of e-mail notification.

The value (specified in days) can be a negative number to specify any number of days in the past or a positive number to specify any number of days in the future.

If a value of 0 is specified for both TrackAhead and TrackBack options, WFM Daemon tracks data changes without date range limitations. If only one of these option values is set to 0, Daemon treats it as an indicator of the current day.

TrackBack

Default Value: 0
Valid Values: Any integer, positive or negative
Changes Take Effect: After restart
Dependencies: TrackAhead

This option is mandatory.

Specifies the number of days back from the current date that WFM Daemon requests data from WFM Server. Relevant for any type of e-mail notification.

The value (specified in days) can be a negative number to specify any number of days in the past or a positive number to specify any number of days in the future.

If a value of 0 is specified for both TrackBack and TrackAhead options, WFM Daemon tracks data changes without date range limitations. If only one of these option values is set to 0, Daemon treats it as an indicator of the current day.