Jump to: navigation, search

StartCallRecording

This operation is part of the Voice API section of the Web Services API.

Overview

Starts call recording. Recording stops when the call is completed or you use the StopCallRecording operation on either the call or the device.


Request URL /api/v2/me/calls/{id}
HTTP method POST
Mandatory Header Authorization: Basic xxxxx=Origin: server-url
Required features api-voice-recording


Parameters

Parameter Value
operationName StartCallRecording


Sample

Request

POST /api/v2/me/calls/01RCC3N118B1V0SL8O7GK2LAES00000V
{
  "operationName": "StartCallRecording"
}

HTTP response

{
  "statusCode": 0
}

CometD notification

{  
   "data":{  
      "notificationType":"CallRecordingStateChange",
      "call":{  
         "id":"01RCC3N118B1V0SL8O7GK2LAES00000V",
         "state":"Established",
         "callUuid":"01RCC3N118B1V0SL8O7GK2LAES00000V",
         "connId":"007102719818001f",
         "deviceUri":"http://127.0.0.1:8080/api/v2/devices/631608b3-ceb1-472b-ba05-2ae39555b0d1",
         "participants":[  
            {  
               "e164Number":"",
               "formattedPhoneNumber":"15001",
               "phoneNumber":"15001",
               "digits":"15001"
            }
         ],
         "dnis":"15001",
         "callType":"Internal",
         "capabilities":[  
            "UpdateUserData",
            "SendDtmf",
            "InitiateConference",
            "Hold",
            "SingleStepTransfer",
            "InitiateTransfer",
            "AttachUserData",
            "DeleteUserDataPair",
            "SingleStepConference",
            "DeleteUserData",
            "Hangup",
            "PauseCallRecording",
            "StopCallRecording"
         ],
         "userData":{  
            "GSIP_RECORD":"ON",
            "IW_BundleUid":"717f9130-a1d9-4092-f8b9-7804ee2592ea",
            "IW_CaseUid":"d7e2c775-edaa-4d1e-b65c-bd48371b43ad",
            "GSIP_REC_FN":"01RCC3N118B1V0SL8O7GK2LAES00000V_15000_15000_15001_2015-10-16_14-26-23_hpe-voicevm-70-dot-genesyslab-dot-com__%3Ccont_center_id%3E"
         },
         "duration":"34",
         "mute":"Off",
         "recordingState":"Recording",
         "supervisorListeningIn":false,
         "monitoredUserMuted":false,
         "monitoring":false,
         "uri":"http://127.0.0.1:8080/api/v2/me/calls/01RCC3N118B1V0SL8O7GK2LAES00000V",
         "path":"/calls/01RCC3N118B1V0SL8O7GK2LAES00000V"
      },
      "phoneNumber":"15000",
      "messageType":"CallStateChangeMessage"
   },
   "channel":"/v2/me/calls"
}
This page was last edited on October 31, 2023, at 13:26.