Dynamic PDF generation for web-based content is temporarily unavailable. This maintenance affects dynamic PDF files that are generated from either the HTML-based page or manual that you are viewing. Links that normally allow this functionality have been hidden, and will reappear as soon as the feature is restored.


Note: Access to static files, including PDF files that are not dynamically generated from our web-based content, is unaffected.

Jump to: navigation, search

Testing Alarm Conditions

Start

  1. Use Telnet to access the VM Server Virtual IP interface.
  2. Open the Solution Control Interface (SCI).
  3. Under Alarm Conditions, select the Alarm Condition that you created in SCS Alarm Conditions.
    For example:
    ALRM_VM_HABackup — right-click it, and then click Test.
    The ALRM_VM_HABackup Alarm Condition indicates that the primary VM Server is in backup mode, which triggers the Alarm Reaction scripts that disable the Virtual IP interface at the primary VM Server and enable the Virtual IP interface at the backup VM Server.
  4. Use an ipconfig command to verify that the Virtual IP interface is active on the backup VM Server and that the Virtual IP interface is inactive on the primary VM Server.

End
Next Steps Resultset next.png Back to Task Table: IP Takeover (Windows, Linux)