In the summary table(s) below, type in the Search box to quickly find options, configuration sections, or other values, and/or click a column name to sort the table. Click an option name to link to a full description of the option. Be aware that the default and valid values are the values in effect with the latest release of the software and may have changed since the release you have; refer to the full description of the option to see information for earlier releases.


Power users: Download a CSV file containing default and valid values and descriptions.

The following options are configured at the application level (in other words, on the application object).

Section Option Default Changes Take Effect
Section Option Default Changes Take Effect
general continuous-no-signal 20 Takes effect immediately
general conversation-file-name-prefix conv_ Takes effect after restart
general cpd-file-name-prefix cpd_ Takes effect after restart
general cpd-if-established false Takes effect immediately
general cpd-recording false Takes effect immediately
general destination-busy-timeout 2000 Takes effect immediately
general keep-channels-open false Takes effect immediately
general line-type Takes effect after restart
general location Takes effect after restart
general max-number-ports-to-record 0 Takes effect immediately
general off-hook-delay -1 Takes effect immediately
general off-hook-timeout 1 Takes effect immediately
general on-hook-timeout 1 Takes effect immediately
general out-of-service-attempts 2 Takes effect immediately
general out-of-service-timeout 1 Takes effect immediately
general post-connect-cpd-priority tserver Takes effect immediately
general pre-connect-cpd-priority tserver Takes effect immediately
general sit-detection true Takes effect immediately
general tscall false Takes effect immediately
general tsclear false Takes effect immediately
general use-busy2-as-nu-tone false Takes effect immediately
general use-engaging-lines false Takes effect after restart
general use-fax2-as-am-tone false Takes effect immediately
general wait-off-hook false Takes effect after restart
hmp audio-codecs PCMU Takes effect after restart
hmp engage-cpd-on-call-setup false Takes effect immediately
hmp sip-proxy Takes effect after restart
isdn called-party-number-plan isdn Takes effect immediately
isdn called-party-number-type national Takes effect immediately
isdn calling-party-number Takes effect immediately
isdn calling-party-number-plan isdn Takes effect immediately
isdn calling-party-number-type national Takes effect immediately
isdn engage-cpd-on-call-setup false Takes effect immediately
isdn isdn-trace false Takes effect immediately
isdn isdn-trace-file-name-prefix isdn_ Takes effect immediately
isdn presentation-indicator restricted Takes effect immediately
isdn use-channel-state false Takes effect immediately
isdn user-info-layer-1 g711-ulaw Takes effect immediately
line-side off-hook-bit-mask a-on;b-on; Takes effect immediately
line-side on-hook-bit-mask a-off;b-on; Takes effect immediately
line-side rcv-idle-bit-mask a-off;b-on; Takes effect immediately
line-side snd-idle-bit-mask a-off;b-on; Takes effect immediately
tones busy-tone-1 500;200;0;0;55;40;55;40;4; Takes effect immediately
tones busy-tone-2 500;200;500;200;55;40;55;40;4; Takes effect immediately
tones disconnect-tone 500;200;500;200;55;40;55;40;10; Takes effect immediately
tones extra-dial-tone 401;125;401;125;0;0;0;0;0; Takes effect immediately
tones fax-tone-1 2150;150;0;0;25;-25;0;0;0; Takes effect immediately
tones fax-tone-2 1100;50;0;0;25;-25;0;0;0; Takes effect immediately
tones forth-tone 0;0;0;0;0 Takes effect immediately
tones intl-dial-tone 402;125;402;125;0;0;0;0;0; Takes effect immediately
tones local-dial-tone 400;125;400;125;0;0;0;0;0; Takes effect immediately
tones ring-back-tone-1 450;150;0;0;130;105;580;415;0; Takes effect immediately
tones ring-back-tone-2 450;150;450;150;130;105;580;415;0; Takes effect immediately
tones sit-tone 900;1000;5;50;0;0;0;0;0;0;0;0; Takes effect immediately