startup Section
application-port
Default Value: 0
Valid Values: Any positive integer
Changes Take Effect: Startup only
The configured port of Trusted Application to listen to incoming connections—for example: 6001.
Mandatory when provision-mode=manual.
application-urn
Default Value: No default value
Valid Values: Any application URN defined in the configuration
Changes Take Effect: After restart
Specifies the unique identifier of the application in the deployment. It is assigned when the application is provisioned.
Example: urn:application:Connector_app
Mandatory—must be specified.
application-user-agent
Default Value: Genesys SfB Connector
Valid Values: Any string
Changes Take Effect: Startup only
The part of the user agent string that identifies the application. Can be empty or non-present.
certificate-thumbprint
Default Value: No default value
Valid Values: Thumbprint of existing certificate
Changes Take Effect: Startup only
The thumbprint of the certificate to use for Trusted Application.
Mandatory when provision-mode=manual.
computer-gruu
Default Value: No default value
Valid Values: computerGRUU from Skype for Business configuration
Changes Take Effect: Startup only
Computer GRUU of Trusted Application. The value is unique for each Connector.
Example:
sip:computer1.lyncdco.lab@lyncdco.lab;gruu;opaque=srvr:connector_app:qFBsnVw_QV-oZ_uG-ia3xAAA
Mandatory when provision-mode=manual.
persistent-storage-path
Default Value: No default value
Valid Values: absolute or relative path to existing directory
Changes Take Effect: Startup only
Specifies a directory where Connector creates a persistent file that contains information about the statuses of all conferences scheduled by Connector.
provision-mode
Default Value: manual
Valid Values: auto, manual
Changes Take Effect: Startup only
Introduced: 9.0.000.xx
Defines the provisioning mode the Connector will use for communication with the Skype for Business Server:
- auto—Auto-provisioning mode of work is used.
- manual—Manual provisioning mode of work is used.
For more information about auto-provisioning mode, see Microsoft documentation.
server-address
Default Value:
Valid Values: Any string
Changes Take Effect: After restart
The FQDN of FrontEnd of Skype for Business Server for the UCMA application connection. Example: pool01.lyncdco.lab
server-port
Default Value: 5061
Valid Values: TCP/IP port
Changes Take Effect: Startup only
The port of the FrontEnd pool of Skype for Business for the UCMA application connection.
Example: 5061