To debug issues with CTI Connector (CTIC) and Cisco’s Intelligent Contact Management (ICM) Client, you might not require full logs but specific logs, such as, SIP messages and GED-125 messages.
To obtain these logs, use the following log configuration option and value:
[ems]logconfig.MFSINK option value in the format *|*|*
Where:
Three modules exist within the CTI Connector:
To print logs that are associated with the CTIC Adaptor module; use a value of 171; For the ICM Client module, use a value of 173 . Examples
The following table contains the ULIDs that are reserved for the CTIC Adapter and ICM Client.
ULID | Configuration | Option Description |
CTICAdapter | ||
1554 | CTICA_CALLFLOW_SIP | |
ICM Client | ||
1626 | ICMC_MESSAGE_EXCHANGE_INFO | All messages exchanged between CTIC & ICM. |
1634 | ICMC_CALL_INFO | Session-specific logs. For example, OPEN/CLOSE. |
1637 | ICMC_SESSION_INFO | Call-specific logs. |
Print a Call Statistics Summary to a log file by using the following configuration: [CTIC] LogMIBStatsInterval=180
Set this configuration option to -1 to disable this feature. The default value is 180. The minimum and maximum values for this option are 30 and 1800, respectively. See the following sample Call Statistics Summary:
Sample Call Statistics Summary: