9.0.006.03
Genesys Pulse Release Notes
Release Date | Release Type | Restrictions | AIX | Linux | Mac | Solaris | Windows |
---|---|---|---|---|---|---|---|
05/31/21 | Update | X | X |
Helpful Links
Releases Info
Product Documentation
Genesys Products
What's New
This release contains the following new features and enhancements:
- New option protocol_timeout is added to the pulse.properties file to allow Genesys Pulse to operate without restart after the connection to Configuration Server is lost.
- protocol_timeout
- Default Value: 30000
- Valid Values: Any positive number
- Changes Take Effect: After restart
- Specifies timeout, in milliseconds, for a connection with Configuration Server.
- (WBRT-15456)
- protocol_timeout
- The following new database-related timeouts:
- In DAP objects for jdbc connection:
- [Pulse]/connect_timeout. Default Value: 30 seconds
- [Pulse]/login_timeout. Default Value: 30 seconds
- [Pulse]/socket_timeout. Default Value: 30 seconds
- These options are directly used in the PostgreSQL connection string and do not affect other databases.
- In the Genesys Pulse application object:
- [pulse]/database_max_wait_timeout. The amount of time, in seconds, to wait for a connection. Default value is 10 seconds. Applicable only to PostgreSQL and Microsoft SQL.
- [pulse]/database_query_timeout. The amount of time, in seconds, to wait for a query to the database to finish. Default value is 300 seconds.
- [pulse]/database_validation_query_timeout. The amount of time, in seconds, to wait for a query to the database to finish when checking a connection. Default value is 10 seconds.
- (WBRT-15391)
- In DAP objects for jdbc connection:
Resolved Issues
This release contains the following resolved issues:
Genesys Pulse no longer converts values of the jdbc_url option to lowercase. (WBRT-15583)
Users can now move Dashboard, Wallboard, and Widget Template objects between folders in Configuration Server when the [pulse]\folder_based_access option is enabled. Previously, prior to moving the object to a desired folder, this object had to be first moved to the Genesys Pulse folder. (WBRT-15352)
Genesys Pulse User Interface now properly manages different Genesys Pulse installations on the same host. (WBRT-15184)
The Grid Widget now restores its size after the browser's window size is restored. (WBRT-15075)
Upgrade Notes
No special procedure is required to upgrade to release 9.0.006.03.