8.5.000.02

Reporting and Analytics Aggregates Release Notes

Release Date Release Type Restrictions AIX Linux Solaris Windows
02/25/16 General X X X X

Helpful Links

What's New

This release contains the following new features and enhancements:

  • Beginning with this release, RAA 8.5 supports Callback reporting. This includes a new table (AGT_CALLBACK), and view (AG2_CALLBACK). For more information, see the Physical Data Model documentation for your RDBMS (available from Reporting and Analytics Aggregates documentation).
  • Support for Red Hat Enterprise Linux AP 64-bit x86 7 operating system. See the Supported Operating Environment: Genesys Interactive Insights page for more detailed information and a list of all supported operating systems.
  • The procedure to apply the partition kit has been simplified. Beginning with this release, apply the partition kit by enabling partitioned-gim in the database. This automatically applies the partition kit. Optionally, you can customize the partition kit using the partition-kit.ss. To do so:
    1. Disable partition-gim in the database.
    2. Edit the partition-kit.ss file, and save it in the RAA root directory (the same directory where GIMAgg.jar is found).
    If you enable partition-gim in the database, partition-kit.ss is not used, and Genesys recommends renaming the partition-kit.ss file to avoid confusion (for example, as NOT_USED_partition-kit.ss). As part of this change, the following files, found in the script directory in past releases, are not included with this release, and are no longer supported:
    • partition-kit-MSSQL.ss
    • partition-kit-ORACLE.ss
    • partition-kit-MSSQL.ss



Resolved Issues

This release contains no resolved issues.



Upgrade Notes

Refer to the Deployment Procedure for this release to deploy the installation package within your environment.

This page was last edited on July 31, 2017, at 16:46.