8.5.200.12
Genesys Rules System Rules Engine Release Notes
Release Date | Release Type | Restrictions | AIX | Linux | Solaris | Windows |
---|---|---|---|---|---|---|
09/23/15 | Hot Fix | X | X | X | X |
Helpful Links
Releases Info
Product Documentation
Genesys Products
What's New
This release contains the following new features and enhancements:
- Memory MonitorβTo solve a problem with handling of OutOfMemory errors, a Memory Monitor has been implemented in GRE. It is designed to periodically check GRE's memory usage, and set its operational state to "over threshold" if memory usage exceeds the configured threshold. The state is reset to back to "normal" if memory usage comes back below the threshold. It also provides an option ("adaptive" strategy) to automatically adjust the configured threshold if an out-of-memory error occurs before threshold is reached (for example, if the configured threshold was set too high). MORE DETAILS.
Resolved Issues
This release contains the following resolved issues:
Previously, when the Configuration Server connection was lost and then reconnected, a new connection to the LCA was created, but the old one was never destroyed. Now, when the Configuration Server connection is re-established, GRE re-uses the existing LCA connection. (GRS-2754)
A slow memory leak causing the server to run out of heap memory and stop responding has been resolved. (GRS-2744)
Upgrade Notes
No special procedure is required to upgrade to release 8.5.200.12.
This page was last edited on September 23, 2015, at 15:14.