Release Date | Release Type | Restrictions | AIX | Linux | Solaris | Windows |
---|---|---|---|---|---|---|
04/17/15 | General | X | X |
This release contains the following new features and enhancements:
You can read about additional CPD functionality in "Appendix C: Tuning Call Progress Detection" of the GVP 8.5 User's Guide. |
This release contains the following resolved issues:
Media Control Platform now plays a dynamic prompt correctly. Previously, MCP incorrectly encoded the symbols < , > and & in SSML tags before queuing a dynamic prompt to TTS.
Use the new parameter com.genesyslab.escapespecialchars in the VXML application to specify not encoding the special characters before queuing the prompt, and thus avoiding the problem.
The option [ems] rc.amq_connection_send_timeout (new in GVP 8.5.1) in the Media Control Platform application specifies the maximum time in seconds to wait for ActiveMQ Producer send message response.
Option: rc.amq_connection_send_timeout
Section: ems
Valid Value: An integer >= 45 seconds
Default Value: 60
Takes Effect: At start/restart
Use this option to compensate for network disconnect or congestion issues that may block the connection to Reporting Server, by giving MCP more time to wait for the ActiveMQ Producer Send Message response after sending a message. The blocked connection is released once the configured timeout expires.
(GVP-22155)
With the option [mpc]rtp.senduponrecv set to 1, Media Control Platform now plays the next announcement after playing the first. Previously when using this option, MCP sometimes waited for a trigger that never arrived, and thus did not play the next announcements. (GVP-22151)
Now when two calls with recording enabled are joined successfully, both ends can hear each other. (GVP-22134)
Media Control Platform now obeys the new setting of the configuration parameter mpc.cpa.maxrings, following a change. Previously, changing the value had no effect. (GVP-22124)
Media Control Platform RTP threads no longer become stuck if they are idle for 25 days. (GVP-22045)
The BRIA4.1 video conference now works properly. Previously, the BRIA4.1 video conference failed after a re-INVITE and displayed only the Genesys logo. (GVP-21993)
Media Control Platform now updates Play cache entries correctly, when Content-Type for a file on the websever is modified to a different type. (GVP-21948)
Media Control Platform now correctly handles a fetch failure. Previously, a fetch failure during root initialization caused the Next Generation Interpreter (NGi) to go into an infinite loop. (GVP-21904)
MCP no longer changes the SDP when responding to a SIP Session Refresh re-INVITE. (GVP-21843)
Media Control Platform can now play a stereo MP3 file for a coaching conference scenario. (GVP-21528)
Media Control Platform now cleans up PEM files from the recording cache correctly, when an mp3 encoder error is encountered during encrypted recording. (GVP-21476)
Media Control Platform no longer uses excessive memory over time, when DOM Object is returned from the subdialog in a VXML application. (GVP-21463)
Resource Manager no longer rejects a Picture Fast Update INFO request that was sent by Media Control Platform during a bridge transfer. (GVP-21415)
Inband DTMF is no longer garbled during recorded conferences. (GVP-21396)
Media Control Platform no longer terminates when releasing a reference to VGMediaInfo. (GVP-19474)
No special procedure is required to upgrade to release 8.5.130.82.