Jump to: navigation, search

8.5.000.15

Genesys Pulse Collector Release Notes

Release Date Release Type Restrictions AIX Linux Solaris Windows
07/31/14 General X X

Helpful Links

What's New

  • The following changes are made to configuration options:

    • Removed the [layout-history], [parallel-processing], [thresholds], and [transport-gpb-history] sections.
    • In the [collector] section:
      • Removed the history-transport option.
    • In the [configuration-monitoring] section:
      • Added the excluded-objects-propagation-delay and remove-dynamic-object-delay options.
      • Removed the auto-detect-dynamic-metagroups, enable-differential-layout-recheck, recheck-active-layout-definition, and strict-tenant-security options.
    • In the [layout-validation] section:
      • Renamed the enable-strict-tenant-security-validation-rule option to validate-strict-tenant-security.
    • In the [limits] section:
      • Removed the max-custom-actions-per-layout, max-custom-thresholds-per-layout, and max-threshold-associations-per-layout options.
    • In the [output] section:
      • Added the collector-snapshot-log-level and snapshot-log-level options.
      • Removed the cleanup-output option.
    • In the [scripting] section:
      • Added the stop-compute-formula-threshold-for-snapshot option.
      • Removed the cumulative-formula-script-execution-timeout, cumulative-threshold-script-execution-timeout, enable-extended-statistic-value, post-processing-script-execution-timeout, and threshold-script-execution-timeout options.
    • In the [statistics-request-handling] section:
      • Removed the optimize-statistic-requests options.
    • In the [transport-gpb-out] section:
      • Added the output-file-mode option.
      • Removed the backend-file-ext, cleanup-file-modification-age-threshold, generate-layout-info-file, and output-format options.


Resolved Issues


When the reconnection timeout configuration option of the Configuration Server application object is set to 0 (zero), Genesys Pulse Collector now successfully reverts the reconnection timeout to the default value (10 seconds). (WBRT-3220)


Genesys Pulse Collector can now process layouts that include Campaign Groups based on Place Groups. (WBRT-3207)


Genesys Pulse Collector no longer leaks memory upon rechecking a layout configuration. (WBRT-2561, WBRT-1479)



Upgrade Notes

Refer to the Deployment Procedure for this release to deploy the installation package within your environment.

Supported Languages

See Release 8.5.1 Translation Support.

This page was last edited on May 12, 2017, at 18:43.