Release Number | AIX | HP-UX | Linux | Solaris | Tru64 UNIX | Windows |
---|---|---|---|---|---|---|
7.6.100.01 [01/09/2012] – General | X | |||||
7.6.000.06 [08/25/2011] – General | X | |||||
7.6.000.05 [06/30/2010] – General | X |
As of February 1, 2012, Genesys is no longer an affiliate of Alcatel-Lucent; any indication of such affiliation within Genesys products or packaging is no longer applicable. Please see the Genesys website at http://www.genesyslab.com for more details.
This release note applies to all 7.6 releases of Data Modeling Assistant (DMA).
Genesys follows applicable third-party redistribution policies to the extent that Genesys solutions utilize third-party functionality. For additional information on third-party software used in this product, see the Read Me. Please contact your technical support representative if you have any questions.
Supported Operating Systems
New in This Release
Corrections and Modifications
There are no restrictions for this release. This release of Data Modeling Assistant does not contain new features or functionality.
This release also includes the following corrections and modifications:
DMA now correctly updates statistics in the Templates after the TimeRanges
and/or
Filters
are modified. Previously, when this occurred, DMA did not update the statistic parameters.
(ER#s 268899929 and 265733888)
DMA now correctly refreshes the description of filters
, time ranges
, time
profiles
, and statistical types
after they are modified. (ER# 262631896)
The CallConferenceOriginated
mask is no longer missing from the DMA Statistic Type constructor.
(ER# 241774289)
DMA no longer terminates when opening a Data Sourcer application that has a backup Data Sourcer application configured. (ER# 226784563)
Supported Operating Systems
New in This Release
Corrections and Modifications
There are no restrictions for this release. This release of Data Modeling Assistant does not contain new features or functionality.
Note: Data Modeling Assistant 7.6.000.06 was originally released on November 4, 2010. Effective August 25, 2011, Build 3 of this release includes support for the Windows 2008 operating system. Customers who obtained this software release prior to that date and need support for Windows 2008 must download Build 3 from the Genesys Software Download website.
This release also includes the following corrections and modifications:
DMA supports a new command, Recheck,
for active layouts. This command is available from the main
menu and context menus on the layout tree and layout list, as well as from the toolbar (the icon with the bell
sign). Executing this command forces Data Sourcer to perform a configuration recheck procedure for the chosen
layout.
(ER# 261923295)
Supported Operating Systems
New in This Release
Corrections and Modifications
There are no restrictions for this release. This initial 7.6 release of Data Modeling Assistant does not contain new features or functionality.
This release includes the following corrections and modifications that were made between Release 7.2 or earlier releases and the initial 7.6 release:
DMA now only creates a new column if the column name, statistic type, or statistical parameters have been modified, otherwise the description will be updated. If there are no changes, DMA will take no action. Previously, DMA created new column in the ODS database if the description changed when the layout template column definition was modified. (ER# 203847648)
This section provides the latest information on known issues and recommendations associated with this product.
During DMA installation on a Windows 2008 environment, you might see a DLL self-registration error. This message can be safely ignored. (ER# 284271931)
Found In: 7.6.100.01 | Fixed In: |
DMA may become unstable on the Windows XP platform when opening a Data Sourcer application that has a backup Data Sourcer application configured. (ER# 226784563)
Found In: 7.2.003.03 | Fixed In: 7.6.100.01 |
After re-synchronizing with Stat Server, DMA may incorrectly set the CollectorDefault
time
profile to null.
In this case, you must manually correct the time profile as follows:
Application
properties.Options
tab and open the TimeProfiles
section to edit the
CollectorDefault
time profile.0:00+0:15
, or a custom definition that is applicable to your
system.(ER# 215606301)
Found In: 7.2.003.01 | Fixed In: |
At the Select DataSourcer Application
screen, DMA displays only those Data Sourcer applications that are configured as primary applications. This is the intended behavior. Upon selection, DMA will automatically connect to both the specified primary and its associated backup. (ER# 114713789)
Found In: 7.2.001.01 | Fixed In: |
Data Sourcer informs DMA about DB Server disconnects, but it fails to inform DMA of its successful reconnection. As such, DMA displays errors, such as Cannot Execute SQL
, when requests to display data are made. Restarting DMA will resolve this problem. (ER# 82639628)
Found In: 7.2.001.00 | Fixed In: |
The warning message that appears, when connection to DB Server is lost, requires a double-click operation to clear the message. (ER# 46734824)
Found In: 7.2.001.00 | Fixed In: |
When the connection to DB Server is lost, DMA may display a long error message that includes a failed query. (ER# 36203207)
Found In: 7.2.000.03 | Fixed In: |
When DMA is working with DB Server and becomes disconnected, DMA must be restarted. Otherwise, any operation with the ODS database may fail, including:
(ER# 22657142)
Found In: 7.1.000.04 | Fixed In: |
You may not be able to create custom report layouts while DMA is connected to a backup DB Server. Make sure that you create custom report layouts only when DMA is connected to the primary DB Server. (ER# 100307)
Found In: 7.0.200.03 | Fixed In: |
The keyboard shortcut for deleting custom Layout Templates does not work in
this release. Instead, use the Delete
menu item from the Edit
menu
to delete custom Layout Templates. (ER# 89839)
Found In: 7.0.100.07 | Fixed In: |
Under certain circumstances, DMA may allow the creation of a Layout Template
containing a blank (null) name in the Report Layout
Name field. Genesys
recommends that you always specify non-null, default, report layout names for the
Layout Templates you create. (ER# 89954)
Found In: 7.0.100.07 | Fixed In: |
DMA does not inform you when it loses its connection with Configuration Server. Furthermore, DMA does not attempt to connect to a backup Configuration Server, even if one has been specified. (ER# 94968)
Found In: 7.0.100.07 | Fixed In: |
Solution names, displayed as layout template attributes, may not correspond to the official Genesys Solution names. (ER# 62441)
Found In: 7.0.000.01 | Fixed In: |
This section documents features that are no longer supported in this software. This cumulative list is in release-number order with the most recently discontinued features at the top of the list.
Support for the following operating systems and RDBMS has been discontinued:
Discontinued As Of: 7.6.100.01 |
Oracle 8.1.7 is no longer supported.
Discontinued As Of: 7.6 |
DB2 8.1 is no longer supported.
Discontinued As Of: 7.6 |
Information in this section is included for international customers.
Some characters in DMA's graphical user interface may appear truncated, depending on your font size. (ER# 6344061)
Found In: 6.5.001.05 | Fixed In: |
On UNICODE systems, such as Japanese, report layout names are limited to 32 characters. DMA, however, mistakenly displays a 64-character limitation in the error message that results when you try to exceed the 32-character limitation. (ER# 90483)
Found In: 7.0.100.07 | Fixed In: |
Additional information on Genesys Telecommunications Laboratories, Inc. is available on our Technical Support website. The following documentation also contains information about this software. Please consult the Deployment Guide first.
Reporting 7.6 Data Modeling Assistant Help describes the DMA user interface and the steps for report layout and layout template creation.
Reporting 8.0 Deployment Guide describes how to configure, install, start, and stop Data Modeling Assistant.
Reporting 8.0 Reference Manual includes component performance measurements.
Reporting 8.0 Master Index directs you to the location of specific topics in the Reporting documentation set.
Product documentation is provided on the Technical Support website, the Genesys Documentation wiki, and the Documentation Library DVD (produced monthly) or the Developer Documentation CD.
Note: For the DVD/CD, the New Documents on this DVD/CD page indicates the production date for that disc. Due to disc production schedules, documentation on the Technical Support website may be more up-to-date than what is available on disc immediately after a product is released or updated. To determine the version of a document, check the version number that is located on the second page in PDFs or on the About This File topic in Help files.