Jump to: navigation, search

GRS Log Events/Alarms

The following log events/alarms are used in Genesys Rules System.

Code Type Type Detail Text/Explanation
21300 ALARM BRS_ERROR_MESSAGE %s Application entry not found in bootstrapconfig.xml for application id XXX

Explanation: This is a configuration error with GRAT/GRE, the application entry could not be located in the bootstrapconfig.xml file.

21324 ALARM BRS_ERROR_MESSAGE %s Received null response

Explanation: There is a connectivity issue between GRAT/GRE and the Configuration Server. GRAT/GRE is unable to send messages to Configuration Server.

21325 ALARM BRS_ERROR_MESSAGE %s Received error from Configuration Server: xxx, yyy

Explanation: There is a connectivity issue between GRAT/GRE and the Configuration Server. GRAT/GRE received an error "xxx" when receiving data from Configuration Server.

21342 ALARM BRS_ERROR_MESSAGE %s Run time exception XXX

Explanation: A runtime exception occurred when communicating with Configuration Server. The details of the message(s) will be shown in 'XXX'

21351 ALARM BRS_ERROR_MESSAGE %s Could not connect to the primary configuration server XXX and a backup configuration server was not defined.

Explanation: A failure occurred connecting to the primary Configuration Server specified in bootstrapconfig.xml, and since no backup Configuration Server was defined, this alarm was issued.

21352 ALARM BRS_ERROR_MESSAGE %s Could not connect to the primary configuration server XXX

Explanation: A failure occurred connecting to the primary Configuration Server specified in bootstrapconfig.xml. The backup Configuration Server will be attempted.

21359 ALARM BRS_ERROR_MESSAGE %s Could not connect to the backup server XXX

Explanation: A failure occurred connecting to the primary Configuration Server specified in bootstrapconfig.xml. Connection to the backup Configuration Server was attempted, but failed.

21363 ALARM BRS_ERROR_MESSAGE %s connect(): caught exception while opening connection to server 'XXX'. Nested exception: 'YYY'

Explanation: A protocol exception occurred communicating to server (XXX). Details are provided in exception text (YYY)

21368 ALARM BRS_ERROR_MESSAGE %s ServerListener: caught exception on handleMessage: "XXX"

Explanation: An unexpected exception occurred when handling a message from Configuration Server. The details are provided in (YYY).

21369 ALARM BRS_ERROR_MESSAGE %s processMessage(): message is lost because message receiver is full

Explanation: A message from Configuration Server to GRAT/GRE was lost because the message receiver queue was full.

21380 ALARM BRS_ERROR_MESSAGE %s Caught exception while submitting request ["XXX"] to server: YYY

Explanation: A protocol exception occurred when submitting a request message (XXX) to Configuration Server (YYY).

21393 ALARM BRS_ERROR_MESSAGE %s Caught exception while opening connection to server 'XXX'. Nested exception: YYY

Explanation: An unexpected exception occurred connecting to Configuration Server XXX, details are provided in YYY.

This page was last edited on May 10, 2016, at 09:25.