Dynamic PDF generation for web-based content is temporarily unavailable. This maintenance affects dynamic PDF files that are generated from either the HTML-based page or manual that you are viewing. Links that normally allow this functionality have been hidden, and will reappear as soon as the feature is restored.


Note: Access to static files, including PDF files that are not dynamically generated from our web-based content, is unaffected.

Jump to: navigation, search

app-switchover-timeout

Section: general
Default Value: 60
Valid Values: 0 or any positive integer
Changes Take Effect: Immediately


Specifies the time interval, in seconds, that Solution Control Server waits for the switchover of an HA application to complete. When the timeout expires, Solution Control Server logs that the switchover operation has failed and allows the next switchover operation. When set to 0, the timer is disabled and Solution Control Server does not allow the subsequent switchover of a HA application in case of a switchover failure.

8.5.100.41

Solution Control Server Release Notes


Solution Control Server is part of 9.x starting in 8.5.100.25.
Release Date Release Type Restrictions AIX Linux Solaris Windows
07/30/19 General X X X X


Helpful Links

Releases Info


Product Documentation

Management Framework

Genesys Products

List of Release Notes

What's New

This release contains the following new feature or enhancement:


Resolved Issues

This release contains the following resolved issue:


When a switchover of an HA application fails, Solution Control Server now allows the next switchover after the time specified by the app-switchover-timeout option elapses. Previously in this scenario, subsequent switchovers were not allowed. (MFWK-21826)